Why Is The Field Joint Coating Of 3PE Anti-Corrosion Layers So Critical?

Nov 26, 2026 Leave a message

In insulated pipeline projects, while the quality of the insulation layer and the outer protective casing often receives the most attention, the anti-corrosion coating on the steel carrier pipe itself is equally vital to the pipeline's service life. For pipelines transporting corrosive media or passing through corrosive soil, any defect in the anti-corrosion coating will serve as a starting point for corrosion on the steel pipe. The 3PE (three-layer polyethylene) coating is a common solution, consisting of an epoxy powder primer, an adhesive intermediate layer, and a polyethylene top layer.


In one specific pipeline project, for instance, a high-temperature-resistant 2PE/3PE external coating system was used. The total thickness of the coating was specified to be at least 2.0 mm, with the epoxy powder layer measuring no less than 120 μm and the adhesive layer no less than 170 μm. At both ends of each coated pipe, an uncoated section of 110 mm to 120 mm was left, with the edge of the polyethylene layer beveled at an angle of no more than 30°.

 

Field joint coating-the process of restoring the anti-corrosion layer at welded joints-is a critical step in ensuring the integrity of the entire coating system. Once welding is complete, the anti-corrosion layer must be reapplied at the weld site. When using heat-shrinkable sleeves for this purpose, the accompanying epoxy primer must be mixed thoroughly on-site. It must reach a dry film thickness of at least 200 μm (some projects require 300 μm), and the heat-shrinkable sleeve should only be installed once the primer has fully cured and passed inspection. The overlap between the heat-shrinkable sleeve and the existing polyethylene coating must be at least 100 mm. Before application, the joint area must be cleaned-removing burrs, weld spatter, and debris-and the surface must be blast-cleaned to an Sa 2.5 standard. Additionally, the polyethylene surface in the overlap zone must be abraded to increase roughness.

news-1600-1200


Once the field joint coating is applied, its integrity is typically verified using a holiday detector (spark tester). The quality of these field joint coatings directly impacts the service life of the entire pipeline and represents a crucial control point during anti-corrosion construction.


For pipelines that require both anti-corrosion and thermal insulation, the sequencing of the anti-corrosion and insulation application processes must be carefully coordinated. If the field joint coating is substandard, even the best-applied insulation layer cannot prevent the steel pipe from corroding.

 