News

Selection Of Heating Pipelines For High-Temperature Steam Applications

Nov 25, 2026 Leave a message

Definition of Applicable Operating Conditions

Suitable for heating systems in industrial facilities, municipal steam trunk networks, and the transport of high-temperature heat sources. Key parameters include: heating medium consisting of saturated or superheated steam; temperatures ranging from 120°C to 350°C; and operating pressures between 1.0 and 2.5 MPa. Due to the high-temperature, high-pressure environment and significant thermal expansion/contraction, these applications demand exceptional heat resistance, structural stability, and sealing performance. Conventional plastic-jacketed pre-insulated pipes are entirely unsuitable for these conditions.

 

Selection of Direct-Buried Pipelines

1. Primary Pipeline Type
The only suitable type is the "steel-in-steel" (steel-cased) pre-insulated direct-buried steam pipeline, consisting of an inner steel carrier pipe, a high-temperature-resistant insulation layer, and an outer steel protective casing.
2. Advantages of This Selection
The dual-steel structure allows the inner pipe to withstand the pressure and temperature of the steam, while the outer steel casing bears soil pressure and mechanical loads. The space between them is filled with high-temperature-resistant insulation materials-such as aluminum silicate or glass wool-which effectively prevent the carbonization or degradation of the insulation layer under high-temperature conditions. The overall high rigidity of the pipeline accommodates thermal expansion and contraction. Furthermore, integrated drainage and moisture-venting systems prevent corrosion caused by groundwater accumulation, ensuring a service life of over 20 years.
3. Applicable Scenarios and Construction Requirements
Suitable for municipal steam trunk networks, underground steam lines in industrial zones, and high-temperature heating mains in urban areas where landscape aesthetics are a priority. Construction must strictly adhere to the "Technical Specification for Direct-Buried Steam Heating Pipelines in Urban Areas." This includes the installation of expansion compensation devices, steam traps, and moisture-venting pipes to prevent pipeline cracking caused by thermal deformation.

 

Selection of Above-Ground (Overhead) Pipelines

1. Primary Pipeline Type
For above-ground installations, use specialized "steel-in-steel" insulated piping, or a configuration consisting of seamless steel pipe, high-temperature-resistant rock wool insulation, and an outer protective jacket made of aluminum or galvanized steel sheeting.

2. Advantages in Selection and Adaptation
Overhead installation eliminates exposure to soil pressure, allowing for clear visibility of any pipeline deformation and facilitating the identification of potential hazards during high-temperature operation-thereby significantly reducing safety risks for high-temperature steam pipelines. The aluminum outer cladding offers superior weather resistance, including protection against UV radiation and rainwater corrosion, making it well-suited for long-term outdoor use. Furthermore, an overhead support system allows for the flexible placement of expansion joints, fixed supports, and sliding supports, perfectly accommodating the thermal compensation requirements of high-temperature pipelines while ensuring convenient operation, maintenance, and rapid troubleshooting.
3. Suitable Scenarios and Restrictions
Suitable for: Open areas within industrial parks, pipelines extending from heat source plants, and high-temperature steam lines in suburban areas where there are no landscape-related constraints. Not suitable for: Densely populated urban residential areas, core scenic or landscaped zones, or areas along major traffic arteries.

 